While the term “Spray Foam” is often widely used in
construction, there are two different types and each
has its advantages and disadvantage. 
Spray foam has been shunned by window installers
and manufacturers over the years because foams, in
the past, have either continued to expand after trim
has been applied deforming the more pliable vinyl
window frames, or because they have been over used
to fill the gaps left when old windows are removed
and the underlying rough opening has been exposed.
Make sure the foam you use has been tested to
industry standards and is labeled conforming to
standards as a low expansion, low pressure foam.
Most standards applying to window installation do
not delineate between open cell foam and closed 
cell foam, the more popular “minimal expansion”
foams are most frequently used and they are mostly
closed cell. More confusing yet, is when foams are
recommended, the compressed foam tape alternatives
are called out to be open cell.
When it comes to Spray Foams, it helps to under-
stand the differences.Open-cell spray foam (ocSPF)
has a cell structure where the cells are filled with air.
The open-cell structure renders soft, flexible foam,
with a density of about 0.5-0.8 pounds per cubic foot
(pcf). 
The R-value per inch of open-cell foam typically
ranges from R3.6 to R4.5 per inch. Unlike fiberglass
and cellulose, the fine cell structure of ocSPF makes
it air-impermeable at certain thicknesses. The air-
impermeability of ocSPF qualifies it as an air-barrier
material, dramatically reducing air leakage through
the building envelope, significantly lowering the
building’s heating and cooling costs. However, 
ocSPF, like fiberglass and cellulose insulations, 
is moisture-permeable, and may require the installa-
tion of a vapor retarder in colder climates.
Closed-cell spray foam (ccSPF) has a closed cell
structure which yields rigid hard foam, with a 
density of 1.8-2.3 pound per cubic foot (pcf), and 
can provide structural enhancement in certain
framed buildings. The smaller cells trap insulating
gas from the curing, which has a lower thermal 
conductivity than still air, and increases the R-value
to anywhere from R5.8 to R6.9 per inch. 
Like ocSPF, ccSPF is also air impermeable at certain
thicknesses and can qualify as an air-barrier materi-
al. The bigger benefit is that the closed-cell structure
of ccSPF also makes it water-resistant, and is the
only spray foam that can be used where contact with
water is likely.
At a thickness of 1.5 inches, no additional vapor
retarder is required for most applications.
Spray Foam Insulation
Industry tested and labeled as a Low
Pressure/Low Expansion; i.e., will not 
warp or deform windows & doors
Quick Setting Formulation: can be cut or
trimmed in less than 1 hour
Cold Temperature Application: can be
applied in temperatures as low as 14˚F
Insulation Value of R5: makes it an efficient
method for stopping air and moisture 
infiltration
Remains Flexible Once Cured: will not crack
or dry out
•
•
•
•
•
Desired Properties
Note: Be careful, shims can
present a problem as they
extend through the cavity
and can allow water and air
infiltration. Foam Tape used
outside like backer rod 
can seal the opening and
conform to the contours while
allowing drainage.