Step 7 Unfold the Header WRB and lap over the drip cap as shown. Tape the corner cuts with builders tape to make sure there is continuity of the WRB over the flashing. If your door is going to be exposed to direct rainwater and wind, it would be best to use a second flexible flashing seal — over the WRB which is over the first layer of flexible flashing. This second layer of flashing should be lapped to direct water down and out of the wall. If the door is above grade, you may want to install a weep screed along the sill, between the lip of the sill pan and the exterior fin- ish, as shown. This will make sure any water underneath the sill pan can drain as well. Step 7A The brickmould trim outside many entry doors acts like a mounting flange, but it’s dimensions make for some differences in installation. Follow Steps 1 through 5. Place brickmould trimmed door into opening with the brickmould trim against the wall, which has caulk over the flexible flashing. Anchor door as instructed by the manufacturer’s instructions. Brickmould Installation Basic Door Installation Window Fitters Guide to Window Installation 113 ©2022 AWDI, LLC Do not reproduce without permission SAMPLE MANUAL